Three ways to count somatic cells, and what each one costs you
Somatic cell counting is done three ways in practice. They are not variations on a theme — they differ in what the result can be used for. This page sets out what each method gives you, and where CytoVue SCC sits.
CMT, flow cytometry, fluorescence imaging
CytoVue SCC uses the same counting principle as the large reference analysers in a dairy laboratory, in a box that fits on a bench or in a hand.
CMT — chemical
Principle: a reagent reacts with the milk and the gel thickness is read by eye.
What it gives you: cheap, no instrument, no power.
What it cannot give you: a number. It is semi-quantitative and subjective, and two people reading the same sample can grade it differently. It answers “roughly how bad”, not “is this load above 400,000”.
Flow cytometry — reference method
Principle: fluorescent labelling followed by high-speed flow-through detection, as used by FOSS and Bentley analysers.
What it gives you: the widest range, the highest throughput, and the status of industry reference in a large laboratory.
What it cannot give you: a result at the point of sampling. The instrument is large, needs a dedicated bench, trained operators and a maintenance regime, and its cost puts it out of reach of a single farm.
Fluorescence imaging — CytoVue SCC
Principle: fluorescence staining, microscopy imaging and automatic counting — the same counting logic as flow cytometry, applied to an image rather than a stream.
What it gives you: correlation above 0.98 with FOSS and Bentley, the stained image kept as evidence, a fraction of the cost, and a footprint that fits a parlour.
What it trades away: throughput per instrument. 80 tests per hour is enough for a farm, a collection point or an intake laboratory, and not enough for a central reference laboratory running thousands of samples a day.
A number can be argued with. An image can be looked at.
Most somatic cell instruments return a figure. When a supplier disputes a rejected load, that figure is the entire conversation, and the conversation goes nowhere.
CytoVue SCC returns the figure, the grade and the stained image it counted from. A disputed result is settled by reopening the image, not by re-running the sample — which matters when the sample is gone or has been held too long to be valid.
- On screen: somatic cell count, grade classification and the original stained image.
- With the result: sample ID, timestamp, count and image stored together.
- On review: SCC100 overlays annotation on the image; SCC200 shows the image unannotated.

Not just an instrument — a support arrangement that lasts
An instrument bought on price alone becomes expensive the first time it stops and nobody answers.
Independently developed
Core components are developed in-house, so supply does not depend on an imported sub-assembly and quality does not depend on someone else's production schedule.
Short delivery
Units and consumables are held in stock. Installation lead time is measured in days, and technical and service engineers are local to the market.
24-hour response
Support answers within 24 hours, by remote session or on site. In mainland China a spare instrument is provided while yours is repaired, so testing does not stop during harvest.
Lower cost of ownership
Instrument and consumable are both priced for a working farm rather than a reference laboratory, and the per-test cost is what decides whether monitoring happens weekly or never.
Compare against your current method
Send us a set of samples you have already run on your reference instrument. We will return counts, images and the comparison, so the decision rests on your own data.