QuickArray-MEAT — Species Identification System

Real-time PCR on a 16-chamber chip. Up to 15 animal species in 35 minutes, on a bench or in a case.

QuickArray-MEAT benchtop detector and the portable field case
35 min
Sample to species result
15
Species per run, 15-target panel
3 min
Room-temperature lysis
2.7 kg
Benchtop detector
Specification

Detector and field case

Same assay, same chip, same software. The difference is where the instrument can be taken and how it is powered.

ParameterDetector (benchtop)Field case (portable)
PrincipleReal-time fluorescence PCRReal-time fluorescence PCR
Fluorescence2 channels (FAM / ROX)2 channels (FAM / ROX)
Chip chambers1616
Targets4 / 8 / 15 panels, plus custom4 / 8 / 15 panels, plus custom
Detection limit1% (w/w) adulteration1% (w/w) adulteration
Sample pre-treatmentChemical lysis at room temperature, 3 minChemical lysis at room temperature, 3 min
Temperature accuracy±0.1 °C±0.1 °C
Ramp rate6 °C per second6 °C per second
External dimensions210 × 210 × 110 mm530 × 440 × 220 mm
Net weight2.7 kg7.2 kg
Reagent storageRoom temperature, > 6 monthsRoom temperature, > 6 months
PowerDC 24 VDC 24 V
BatteryExternal battery supportedInternal, supports 5 chip runs
Detection limit is expressed as the mass fraction of the adulterant in the sample, following the 1% threshold used in GB/T 38164-2019 for animal-derived ingredient identification. Some matrices allow lower detection; confirm the figure for your matrix before making a claim.
Capability

What the platform is built to do

15 species at once

One chip screens the whole panel in a single run. No sequential single-species testing, no queuing samples behind each other.

35 minutes, not days

A result that arrives while the consignment is still in front of you is a different kind of result from one that arrives after it has cleared.

Raw and cooked meat

Heat-processed products are the hard case because DNA is degraded. The assay is designed for that matrix, not only for fresh tissue.

No cold chain

Chips are stored at room temperature for more than 6 months and shipped without dry ice, which matters for distributors in hot climates.

Carry it to the sample

The 2.7 kg detector can run from a vehicle power supply; the 7.2 kg case carries an internal battery for five chip runs.

Panels fit the market

Where the standard panel does not match a national requirement, a custom panel can be configured around the species that must be declared.

Panels

What each panel screens

Three standard configurations, all on the same chip and the same instrument. Pick the panel that matches the declaration requirement in your market.

QuickArray 16-chamber PCR chip with the 15-species target panel labelled

15-target panel

15 species plus an internal control, reported simultaneously from one 16-chamber chip.

No.Common nameScientific name
1Domestic pigSus scrofa domesticus
2CattleBos taurus
3YakBos grunniens
4Water buffaloBubalus bubalis
5SheepOvis aries
6ChickenGallus gallus domesticus
7Domestic duckAnas platyrhynchos domesticus
8Chinese gooseAnser cygnoides domesticus
9HorseEquus ferus caballus
10DonkeyEquus africanus asinus
11Red foxVulpes vulpes
12Brown ratRattus norvegicus
13American minkNeovison vison
14Domestic rabbitOryctolagus cuniculus
15Domestic dogCanis lupus familiaris
16Internal control—

8-target panel

The eight commercial species that account for most adulteration cases, plus an internal control.

No.Common nameScientific name
1Domestic pigSus scrofa domesticus
2CattleBos taurus
3YakBos grunniens
4SheepOvis aries
5ChickenGallus gallus domesticus
6Domestic duckAnas platyrhynchos domesticus
7HorseEquus ferus caballus
8DonkeyEquus africanus asinus
9Internal control—

Halal Screen panel

One chip answers two questions at once: whether the declared halal species is present, and whether a cheaper species has been substituted for it. The target matrix can be one or several of the six listed; prohibited and controlled species are fixed.

No.Common nameScientific nameStatus
1CattleBos taurusTarget matrix
2SheepOvis ariesTarget matrix
3ChickenGallus gallus domesticusTarget matrix
4Domestic duckAnas platyrhynchos domesticusTarget matrix
5Chinese gooseAnser cygnoides domesticusTarget matrix
6Domestic rabbitOryctolagus cuniculusTarget matrix
7Domestic pigSus scrofa domesticusHaram — core prohibited
8Domestic dogCanis lupus familiarisHaram
9Brown ratRattus norvegicusHaram — illegal low-grade meat
10Red foxVulpes vulpesHaram — fur-farm meat
11American minkNeovison visonHaram — fur-farm meat
12DonkeyEquus africanus asinusHalal-controlled
13HorseEquus ferus caballusHalal-controlled
14Internal control—Internal control
The 4-target panel is a subset of the 8-target panel, configured per order. Panel composition is reviewed as target requirements change — confirm the current list against the specification sheet before ordering.
Applications

Where the system is deployed

Market enforcement

Species verification at the stall, with a result before the inspection ends.

Police evidence collection

Documented on-site screening that supports a subsequent statutory test.

Customs and ports

Declared species versus consignment, screened at the inspection point.

Processor incoming goods

Supplier declaration checked before the batch enters the line.

Halal certification

Absence of non-halal species tested rather than only audited on paper.

Retail and food service

Supply chain spot checks and response to complaints or media reports.

Workflow

Four steps from sample to result

Take the sample

A small piece of meat, raw or cooked, into the lysis tube.

Lyse, 3 minutes

Chemical lysis at room temperature. No heating block, no cold chain.

Load and run, 35 minutes

Add the lysate to the chip, insert the chip, start the run.

Read the result

Software reports which species were detected and exports a printable record.

Output

A species list, not a single yes or no

The software reports each target on the panel as detected or not detected, with the amplification curves available for review. The result can be printed or exported as a record of what was tested and when.

Screening results support inspection and triage decisions. Where a finding is contested, the statutory method in force in the destination market governs.

Amplification curves and the chip map, and the same run as a target list. Click or tap either image to enlarge.
One platform, more than meat. The same instrument and chip architecture can be configured for other nucleic-acid targets, including dairy and plant material screening. Ask about the target set you need.
Service and support

What happens after the instrument arrives

A screening result is only useful if the platform keeps running and the panel keeps matching the market requirement.

ItemWhat is included
Warranty1 year from delivery, parts and labour
Installation and trainingRemote commissioning plus a written operating procedure; on-site training available for fleet orders
Chip supplyStandard panels held in stock, stored and shipped at room temperature; lead time confirmed per order
Panel configurationCustom panels built around the species that must be declared in a given market
Technical supportDirect contact with the engineering team by email or WhatsApp, in English or Chinese
Software updatesFree for the life of the instrument; delivered by USB
DemonstrationDemonstration unit available for evaluation before a fleet order
DocumentsInstruction for Use in English, panel composition sheet, packing list
Questions

Frequently asked

Up to 15, depending on the panel. The 15-target panel screens 15 species simultaneously on one 16-chamber chip; 8- and 4-target panels cover narrower sets for routine screening and single-category verification.

Yes. The assay is designed for heat-processed matrices, where DNA is degraded and morphological identification is impossible. This is the case that matters most, because processed products are where substitution is most often found.

No. Chips carry dried-down reagents and are stored at room temperature with a shelf life of more than 6 months. The lysis step is also at room temperature, in 3 minutes.

Yes. A custom panel can be built around the species combination required by a destination market or a certification scheme. It runs on the same instrument with the same workflow and the same software.

A rapid PCR result supports inspection and screening decisions. Where a finding is contested, the statutory method in force in the destination market governs, and confirmatory testing should follow that method. The instrument produces a printable record of what it detected.

Request a quote for QuickArray-MEAT

Tell us the species you need to detect and where the instrument will be used. We will confirm the panel and the form factor.